| |
PRODUKTE |
| Akkuwächter
|
|
|
| Antennen
|
| |
| Batterie
Controller |
| Batterie
Schalter |
|
| |
|
|
| Dimmer
|
|
| |
| Heizungen
. |
| |
| |
| |
| |
| |
| |
|
|
| |
| |
| |
| |
| |
| Schalttafeln
|
| |
|
|
| |
|
| |
| Solarwärmetechn
|
| |
| |
| Spannungsverteiler
|
| Steckverbinder
|
| |
|
| |
| UKW
Seefunk |
| |
| |
| |
| Wetterempfänger
|
|
| Zeitschaltuhren
|
|
|
TOP
Angebote |
SOLARA semiflexibles Solarmodul mit 42 Solarzellen
SM280M
nur 799,-€
|
|
|
| Solar Dachlüfter
|
|
|
flexible Solarmodule
Schnäppchen
|

SONDERPREIS
nur bei telefonischer Bestellung

SM
120, 34Watt
nur 349,90€
SM160, 45Watt
nur
478,50€
S520P36,
130Watt
nur
639,-
|
Schnäppchen Lithium-Powerbox
4,2Ah statt 232,99 nur
196,-€
solange der Vorrat reicht
|
| |
|
|
NEU
Votronic-Batterie-Controller Pro |
| |
| |
| |
| |
| |
| |
| |
|
|
| WERBUNG |
Solarlink gratuliert zum 25ten Geschäftsjahr
hier könnte Ihre Werbung stehen,
wir unterbreiten Ihnen gern ein Angebot
|
|
|
| |
| |
|
|
x200.gif)
Automatic 4step battery charger
Pro Digital
The new DIGITAL ranges of battery chargers are the latest High Tech up
grade on the above battery chargers. All the power benefits of the standard
system are retained but the control, safety and information aspects have
been upgraded beyond recognition. The latest benefits offered by digital
control system are highlighted in the Quick Check on the opposite page
and should be studied. Digital control ensures more accurate control,
more battery information type storage in the software and more real time
calculations to be done to ensure the best charge. More information is
also available in the control chip which can then be displayed on the
new remote control and information panel which is supplied as a optional
in the small range but as standard in the large range.
Best Buy Winner from Seglen
German yacht magazine test
| PDF
Download |
|
|
Manual |
|
810 KB |
Digital software control
There are 2 ways to control electronic processing, Analogue (hardware
control) and Digital (soft ware control). Hardware control is where the
voltage sensing and processing are all done via transistors and electronic
hardware. This is fine as long as the information to be processed is kept
simple. However an Advanced Regulator may look simple (and most of them
are) but when all the different battery types, bank sizes, and safety
parameters are installed, the unit would become almost impossible to make
and set up. Sterling leads the field in this type of controller but has
found that when upgrading from our previous model that it required so
many extra features to keep up with new battery types and alternator types
etc that it made a hard ware version impossible to make.
Digital control (software): This uses computer lines of code, digitally
burned into a memory processor in the Advanced Regulator. This means that
very complex information and mathematical processes can be processed,
which would be impossible for the hardware system to do. It is the next
generation of control, and more and more you will see the term digital
control appearing on different products. Digital control offers so many
extra features at no extra cost (see below) and accuracy beyond the ability
of the analogue version.
3 isolated outputs:
The charger has 3 outputs enabling 3 different battery banks to be monitored
and charged at the same time.
Automatic 110/230 volt selector:
The in built system enables the charger to be automatically used on a
wide voltage range from 80-300 volts A/C. This covers all the possibilities
encountered on any marine in the world.
Multiple input frequencies from 40-400 Hz:
Self-explanatory, the unit is able to work on all worldwide A/C input
frequencies.
Thermostatically controlled fan cooling:
The digital software monitors the unit temperature and controls the fans;
this reduces any unnecessary fan noise from the charger and prolongs the
fans life for many years.
High ambient temperature rated:
Many boat builders expect the chargers to work at full power continuously
at 40 deg ambient, few chargers in the world meet this specification -
we do.
3 battery type charging curve selector:
There is more than one battery type; most chargers do not offer different
programs for different battery types. Failure to offer an option will
result in either overcharging some battery types and sulphating others.
The Sterling offers charging curves for open lead acid batteries, traction
batteries, sealed batteries, gel batteries and A.G.M batteries.
Automatic battery bank size and state:
No need to program in the battery bank size as the digital software can
work that out itself.
Automatic High Charge timer calculated every time:
Most chargers have a fixed high charger timer, which works regardless
of battery size and state or even load on the boat. The digital processor
is able to discern the battery bank size, what state it is in and even
take into consideration the power used by the boat. It then calculates
the ideal equalizing charger time; this will be different every time and
will be from 1-6 hrs
Automatic 7 day de-sulphation cycle:
The good thing about a constant current charger is that it de-sulphates
the battery plates ensuring maximum life from the batteries. However,
this only works if the charger is switched on/off regularly (i.e. every
time you disconnect and reconnect the charger the plates are subjected
to a de-sulphation cycle). The problem is some boats or standby equipment
may be rarely used. For example, a boat could be moored all year and never
leave the pontoon, or a stand by generator with the charger on all the
time. In these cases the de-sulphation cycle would only happen once and
the batteries would eventually sulphate causing premature destruction.
However the Sterling software has a 7 day timer which in the event of
inactivity will automatically run a de-sulphation cycle keeping your plates
clean.
3 stage R.F.I filter:
In order to meet C.E. requirements for Radio Frequency Interference a
three-stage filter is used to ensure that not only is the standard reached
but also that we fall well above the standard legally required.
Battery temperature sensing and compensation:
The Sterling Digital comes complete with a battery temperature sensor,
which is automatically set to one of the temperature compensation set
by your battery type selector switch.
3 battery temperature sensors: The larger
battery charger range comes complete with 3 temperature sensors, which
monitor and display and react to the 3 different battery banks, including
3 high temp trips
Independent unlimited high battery temp trip circuit: This unit has a
trip circuit which can be connected to any trip device such as temperature
trips or any trip which results in an open circuit. The problem is that
a charger could be attached to 10 batteries but only monitoring 3. However
if you wish you can put a standard temperature trip on every battery and
link them together into a common trip circuit. If any of these batteries
exceed a pre determined value the charger will switch off.
High battery voltage trip:
Things do go wrong no matter how hard we try so in the event of the regulator
control failing, then any voltage above what the software is expecting
will shut the battery charger down and display the fault.
High battery temperature trip:
It is amazing how many companies sense battery temperature and compensate
the charger voltage against temperature. Yet in the extreme event of total
battery failure and the battery is going to boil the battery charger will
not switch off the charger. The Sterling processor not only senses the
temperature but will shut down the charger in event of total failure and
display the fault condition.
High heat sink temp trip:
In the event of extreme temperature or cooling fan failure the battery
charger will switch off at 70 deg C
Auto Power reduction in event of high temperature.
Because it is best to get as much power as possible at high temperature,
in extreme high temperature or cooling fan failure, if the heat sink reaches
65 deg C then the output current of the unit will be systematically reduced
to prevent the high temperature trip being activated at 70 deg C.
7 led output display information panel: High
charger rate, timer activated, battery type (3 colours), Float mode, high
battery temp trip, over voltage trip,
24kt gold plated output terminal posts:
Over a period of time brass corrodes in salt air making poor connectors.
We have all seen the green paste that forms around battery terminals etc.
All Sterling connection posts are solid brass and are 24kt gold plated
to eliminate this for life.
Negative Fused externally (A.B.Y.C requirement):
Because the largest market for our products is in the USA, it is important
to conform to European and USA standards. This is a requirement for the
USA A.B.Y.C boat building code of practice. As a result some electricians
were receiving electric shocks because they thought they were on the D/C
negative system when they were on the 110V A/C system.As a result international
regulation bodies are attempting to change the colour of the D/C negative
cables (which have been black) to yellow, this is already the case in
the U.S.A. for A.B.Y.C. and is under review in the U.K. The negative cable
in the new digital range comes as yellow and a gold fuse is supplied.
Reverse polarity protected:
The supplied fuse blocks offers a good reverse polarity protection system.
Overload protected:
As stated the unit cannot be overloaded.
Short circuit protected:
As stated the cant can be short-circuited with no adverse results.
Remote control socket:
The unit has the ability to be connected to a digital L.C.D. information
and control panel.
Sturdy construction:
The unit is made from extruded aluminium and extremely sturdy, with extra
thick 2.4 mm printed circuit board.
Small footprint:
A modern requirement even on the largest boats is the requirement for
a small foot print size, check our size out. Extra features when connected
to the Digital remote control.
Remote switch on/off:
Self-explanatory.
Manual power reduction selector:
Some marinas offer only limited shore power; as a result high power battery
chargers will not work. It therefore becomes necessary to reduce the out
power of the charger to enable it to operate from the shore power. This
remote offers the ability to select 100%, 50% or 25% power to deal with
the lowest shore power supplies. It's best to have some power rather than
none. This feature is also good if an onboard generator is used, i.e.
you may want say a 100 amp charger for the onboard generator to charge
the batteries fast but the local berth cannot support such a large charger.
In this case the charger could be reduced to 25 amps when returned to
the marina berth.
Auto memory power lock on setting:
If reduced power is selected the software remembers the setting so in
the event of removing the shore power the charger will start up on the
reduced setting next time.
Delay start up to enable power setting
change:
In the event of a boat entering a marina and only a low power supply is
available, if the last time the charger was used, then the charger would
start up on high power and trip the shore supply. To overcome this problem
when the charger is started, the software counts down 30 seconds before
automatically starting the charger on the last setting. This gives the
operator ample time to reduce the power if required on the remote control.
2 line 16 bit L.C.D. display screen:
As
described above a large information screen is use which as an on/off switch
for the background light.
Auto cycle all information with manual screen lock:
Due to the large amount of information being displayed, it is not possible
to fit it all on the screen. As a result the screen automatically scrolls
through the screens. However you may wish to monitor one screen in particular,
in this case simply push the lock button to lock that screen on.
Impressive information displayed:
The L.C.D. display and control gives the following information, charger
amps, charger volts, time remaining on equalizing charger, battery type
selected, battery temperature, charger temperature, plus all alarm and
other control functions.
Surface mount or recess box:
The clever remote control box design means the box can either be surface
mounted on a bulkhead or flush mounted.
| Typ |
12V30A |
12V40A |
12V50A |
24V25A |
Remote Control |
| Voltage |
12Volt |
24Volt |
LCD-Display, 4 Status
LED`s |
| Output Amp. |
30 |
40 |
50 |
25 |
| Batteriekapazität Gel |
75-200 Ah |
100-270 Ah |
125-330 Ah |
60-160 Ah |
| Batteriekapazität Naß |
60-300 Ah |
80-400 Ah |
100-500 Ah |
50-250 Ah |
| LxWxH mm |
340x180x90 |
340x180x90 |
170x90x40 |
| weight kg |
3,3 kg |
3,3 kg |
0,5 kg |
Onlineshop, Preise
finden Sie im Shop |
|
|
|
|
|
| |
|
|
|
|
|
|