| |
PRODUKTE |
| Akkuwächter
|
|
|
| Antennen
|
| |
| Batterie
Controller |
| Batterie
Schalter |
|
| |
|
|
| Dimmer
|
|
| |
| Heizungen
. |
| |
| |
| |
| |
| |
| |
|
|
| |
| |
| |
| |
| |
| Schalttafeln
|
| |
|
|
| |
|
| |
| Solarwärmetechn
|
| |
| |
| Spannungsverteiler
|
| Steckverbinder
|
| |
|
| |
| UKW
Seefunk |
| |
| |
| |
| Wetterempfänger
|
|
| Zeitschaltuhren
|
|
|
TOP
Angebote |
SOLARA semiflexibles Solarmodul mit 42 Solarzellen
SM280M
nur 799,-€
|
|
|
| Solar Dachlüfter
|
|
|
flexible Solarmodule
Schnäppchen
|

SONDERPREIS
nur bei telefonischer Bestellung

SM
120, 34Watt
nur 349,90€
SM160, 45Watt
nur
478,50€
S520P36,
130Watt
nur
639,-
|
Schnäppchen Lithium-Powerbox
4,2Ah statt 232,99 nur
196,-€
solange der Vorrat reicht
|
| |
|
|
NEU
Votronic-Batterie-Controller Pro |
| |
| |
| |
| |
| |
| |
| |
|
|
| WERBUNG |
Solarlink gratuliert zum 25ten Geschäftsjahr
hier könnte Ihre Werbung stehen,
wir unterbreiten Ihnen gern ein Angebot
|
|
|
| |
| |
|
|


Battery monitor BCM
A 16bit microcontroller seizes consumer and charging currents with
very high accuracy over an active precision precisions shunt. On the
large LCD announcement the accurate charge of the service battery
can be read off at any time. Additionally load/discharge current or the
battery voltage is indicated. Parallel to it can be supervised up to 2
starting batteries and indicated their parameter. If one of the attached
batteries reaches an adjustable remainder capacity/tension threshold,
then an acoustic alarm sounds and on the display an appropriate
warning reference appears.
- very high accuracy (10mA) and large capacities (150 A eg. 600A)
- automatic battery full identification and correction of the load factor
- gradual adjusting of effective battery capacity with cycle enterprise
- Indicate to the number of load cycles and over-dischargings- adjustable
nominal battery voltage (12V/24V/36V/48V)
- individual attitude of all parameters such as Peukert exponent,
danger thresholds for remainder capacity and/or tension possible.
Attitudes and measured values remain during switched off current
supply
- Announcement of remainder capacity or remainder time
- highly soluble, background-lit announcement (LCD, 64*128 pixel)
- very low power input 2,5 mA / < 1 mA in sleepmode @ 12VDC for continuos
operation.
- Extension of the data line (up to 100m) with simple means possible.
Interference-resistant data communication during longer data line over
integrated RS485 port
- soft Touch Buttons with intuitive menu guidance, which can be
served pleasantly
Erweitertes Setup der LCD-Anzeige für die Generatorsteuerung
Shunt´s
available in 150 und 600 Ampére
Abb.rechts: Messwiderstand 600 Ampére
| PDF
Download |
|
Prospekt |
|
1,1 MB |
|
Flyer |
|
1,1 MB |

BCM Relais 12Volt, Order-No: 0 7000 1112
BCM Relais 24Volt, Order-No: 0 7000 1124
Abb.rechts Schaltkasten für BCM
please order by e-mail |